An over-the-air (OTA) test method used in 5G that involves
mounting the device under test (DUT) on a positioner that
rotates in azimuth and elevation. This process enables
measurement of the DUT at any angle on the full 3D sphere.
The DFF method can perform the most comprehensive tests
measuring multiple signals and requires a larger test chamber
for mmWave devices.